Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
PLoS Negl Trop Dis ; 17(4): e0011290, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-37058542

RESUMO

BACKGROUND: Chagas disease or American trypanosomiasis, a neglected tropical disease, is a persistent Public Health problem in Latin America and other, non-endemic, countries. Point-of-care (POC) sensitive methods are still needed to improve and extend early diagnosis in acute infections such as congenital Chagas disease. The objective of this study was to analytically evaluate in the lab the performance of a qualitative POC molecular test (Loop-mediated isothermal amplification (LAMP), Eiken, Japan) for rapid diagnosis of congenital Chagas disease employing FTA cards or Whatman 903 filter paper as solid supports for small-scale volumes of human blood. METHODOLOGY/PRINCIPAL FINDINGS: We used human blood samples artificially infected with cultured T. cruzi strains to assess the analytical performance of the test in comparison with liquid blood anticoagulated with heparin. The DNA extraction process was evaluated using the ultrarapid purification system PURE manufactured by Eiken Chemical Company (Tokio, Japan) over artificially infected liquid blood or different amounts of dried blood spot (DBS) 3- and 6-mm pieces of FTA and Whatman 903 paper. LAMP was performed on a AccuBlock (LabNet, USA) heater or in the Loopamp LF-160 incubator (Eiken, Japan), and visualization of results was either done at naked eye, using the LF-160 device or P51 Molecular Fluorescence Viewer (minipcr bio, USA). Best conditions tested showed a limit of detection (LoD) with 95% accuracy (19/20 replicates) of 5 and 20 parasites/mL, respectively for heparinized fluid blood or DBS samples. FTA cards showed better specificity than Whatman 903 filter paper. CONCLUSIONS/SIGNIFICANCE: Procedures to operate LAMP reactions from small volumes of fluid blood or DBS in FTA were standardized for LAMP detection of T. cruzi DNA. Our results encourage prospective studies in neonates born to seropositive women or oral Chagas disease outbreaks to operationally evaluate the method in the field.


Assuntos
Doença de Chagas , Trypanosoma cruzi , Recém-Nascido , Humanos , Feminino , Trypanosoma cruzi/genética , Estudos Prospectivos , Sensibilidade e Especificidade , Técnicas de Amplificação de Ácido Nucleico/métodos , Doença de Chagas/diagnóstico , Doença de Chagas/congênito
2.
Microorganisms ; 10(5)2022 Apr 26.
Artigo em Inglês | MEDLINE | ID: mdl-35630354

RESUMO

A loop-mediated isothermal amplification assay was evaluated as a surrogate marker of treatment failure in Chagas disease (CD). A convenience series of 18 acute or reactivated CD patients who received anti-parasitic treatment with benznidazole was selected-namely, nine orally infected patients: three people living with HIV and CD reactivation, five chronic CD recipients with reactivation after organ transplantation and one seronegative recipient of a kidney and liver transplant from a CD donor. Fifty-four archival samples (venous blood treated with EDTA or guanidinium hydrochloride-EDTA buffer and cerebrospinal fluid) were extracted using a Spin-column manual kit and tested by T. cruzi Loopamp kit (Tc-LAMP, index test) and standardized real-time PCR (qPCR, comparator test). Of them, 23 samples were also extracted using a novel repurposed 3D printer designed for point-of-care DNA extraction (PrintrLab). The agreement between methods was estimated by Cohen's kappa index and Bland-Altman plot analysis. The T. cruzi Loopamp kit was as sensitive as qPCR for detecting parasite DNA in samples with parasite loads higher than 0.5 parasite equivalents/mL and infected with different discrete typing units. The agreement between qPCR and Tc-LAMP (Spin-column) or Tc-LAMP (PrintrLab) was excellent, with a mean difference of 0.02 [CI = -0.58-0.62] and -0.04 [CI = -0.45-0.37] and a Cohen's kappa coefficient of 0.78 [CI = 0.60-0.96] and 0.90 [CI = 0.71 to 1.00], respectively. These findings encourage prospective field studies to validate the use of LAMP as a surrogate marker of treatment failure in CD.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...